Order number
S68120 / S68261
Availability
On request
Documents
Description
- Build as solar module – easily comparable to energy yield and system performance of PV systems
- Optional cell temperature as alternative to directly measured module temperature
- Output signal: 0 … 10V for irradiance and cell temperature
Silicon irradiance sensors show a cost-effective, but rugged and reliable solution for irradiance measurement. Based on the construction of the sensor element corresponding to a PV module they are ideal as reference for monitoring of PV systems. Especially the spectral response comparable to PV modules as well as the similar inclination error (incident angle modifier) allow an exact analysis of PV energy yields using Si sensor data.
Specifications
| Sensor | Si-V-10TC | Si-V-10-TC-T |
|---|---|---|
| Ordner No. | S68120 | S68261 |
| Solar cell | Monocrystalline silicon (50 x 33mm) | |
| Measurement uncertainty Irradiance |
± 5W/m² ±2.5% of reading valid for temperature compensation, spectrum AM 1.5 and vertical light beam |
|
| Measurement uncertainty Internal temp. measurement |
1.0K @ -35 … 70°C 1.1K @ -35 … 80°C |
|
| Response time (99%) | 0.15 s | |
| Offset | 2 W/m² | |
| Non-Linearity | 0.10 % | |
| Temperature dependance | 0.40% @ -35 … 80°C | |
| Power supply | 24VDC (12 … 28VDC) typ. < 1mA power consumption |
24VDC (12 … 28VDC) typ. < 2 mA power consumption |
| Load impedance | min. 100kΩ | |
| Output signal irradiance | 0 … 10V @ 0 … 1500W/m² | |
| Output signal cell temperature | 0 … 10V @ -40 … 90°C | |
| Sensor connection | LiYC11Y 4 x 0.14mm² UL20233; length typical 3 m, UV- and temperature resistant |
|
| Operating temperature | -35 … +80°C | |
| Housing material | Powder-coated aluminium, IP 65 | |
| Dimensions / Weight | 155 x 85 x 39 mm / approx. 350 g | |
| Manufacturer | Ingenieurbüro Mencke & Tegtmeyer GmbH | |
Sensor connection diagram
Si-V-10TC (S68120)
| Sensor | Plug PIN No. | Wire Colour Sensor Cable | Meteo-40 Analog Voltage |
|---|---|---|---|
| Solar irradiance | 1 | orange | Ax |
| Solar irradiance Ground / Ref.* |
Bx (Main Ground) |
||
| Ground / Ref. | 2 | black | Main Ground |
| Supply | 3 | red | 12 … 28 VDC |
*Minus signals are identical to Ground
Cable type: LiYC11Y 4 x 0.14 mm² (cable length: 3m)
Connect the shield logger-sided to Ground (GND)
![]()
Si-V-10TC-T (S68261)
| Sensor | Plug PIN No. | Wire Colour Sensor Cable | Meteo-40 Analog Voltage |
|---|---|---|---|
| Temperature | 1 | brown | Ax |
| Temperature Ground / Ref.* |
Bx (Main Ground) |
||
| Solar irradiance | 2 | orange | Ax+1 |
| Solar irradiance Ground / Ref.* |
Bx+1 (Main Ground) |
||
| Ground / Ref. | 4 | black | Main Ground |
| Supply | 3 | red | 12 … 28 VDC |
*Minus signals are identical to Ground
Cable type: LiYC11Y 4 x 0.14 mm² (cable length: 3m)