Air Pressure Sensor Ammonit AB 60

Air Pressure Sensor Ammonit AB 60

Order number

S31105

Availability

Usually in stock

Accessories

Documents

Download PDF

Description

  • Piezoelectric barometric pressure sensor
  • Low power consumption
  • Operating pressure:
  • 800 … 1100hPa (mbar)

Measurement principle
The piezoelectric pressure sensor’s signal is electronically amplified to provide an output signal of 0…5 VDC.

Mounting

The sensor is mounted in a stainless steel housing, protection class IP64 when the connector is plugged in.
When mounted outside the central steel cabinet we recommend protective housing with pressure compensation.
In measurement operation the sensor needs an external supply of at least 9VDC.

Specifications

Characteristic AB 60
Operating pressure 800 … 1100hPa (mbar)
(Altitude: ≤ 1400m)
Slope 60hPa/V
Offset 800hPa
Temperature operation range -40 … 85°C
Humidity range 0 … 98%RH
Accuracy
Total accuracy (-10 … 60 °C) ±3hPa
Repeatability ±0,6hPa
Long term stability ±0,3hPa/year
Electrical data
Output voltage 0 … 5VDC
Supply voltage 9 … 32V
Current consumption 5mA
General
Dimensions Length 72mm, diameter 22mm
Weight 80g
Housing Stainless steel
Connection 4-pole plug (M12)
Protection class IP 64 – when connector is plugged in
Vibration (5 … 500 Hz) 2gRMS
Mechanical shock 50 g
Atmosphere non-ionic, non-corrosive

* FSO (Full Scale Output) describes the difference of the upper and the lower limit of the pressure range.

Sensor connection diagram

Sensor Plug Pin No. Ammonit Cable Wire Colour Meteo-40
Analog Voltage
Supply
Sensor
Air Pressure
Output Voltage
2 white Ax A
Ground 4 blue Ax B
Supply 1 red 9 … 32VDC
Ground 4 black Main Ground

Cable type: LiYCY 4 x 0.25mm²
Connect the shield logger-sided to Ground (GND)